SDI failed to initialize with signalling library
SDI received an error from the sl_register or sl_open call to the signalling library. SDI terminates, making Blueworx Voice Response telephony unusable. This error is to be expected if you have no telephony devices attached to the system, in which case the lack of SDI will have no effect, because its job is to control the hardware. In other cases this error is fatal, because control of telephony is not possible.
If you are not using any telephony hardware you may ignore this message. In other cases, check the return code given in the Programming for the Signaling Interface information to determine the cause of the error. Restart the AIX system and try again.
Red
Log, System Monitor, Alertable