27037

Invalid common channel signalling trunk configuration

The request to enable a pack has failed because of a configuration error. SDI has detected that the pack has channels that are defined to use more than one type of signalling process. If a trunk is defined to use a common channel signalling protocol, all channels on that trunk must be in channel groups that use the same Signalling Process Type.

Check the setting of the Signalling Process Type parameter for the Channel Group. If it is correct, check the settings of the Channel Group parameter for all the channels on the trunk to ensure that they are all in the same group. The Signalling Process Type must be the same for each channel, but the channels do not have to be in the same group.

Severity

Yellow

Destination

Log, System Monitor