Alarms on T1 and E1

Some of these alarms apply only to T1 systems, and some apply only to E1 systems, as shown in Table 1.

Table 1. Table of alarms for T1 and E1 systems

Alarm

Systems it Applies to

Frame level or Multiframe (E1 only)

AIS

E1, T1

Frame

AIS_16

E1

Multiframe

BPV

T1

 

ER

E1

Frame

FAL

E1

Frame

MF

E1

Multiframe

MF-AL

E1

Multiframe

OOF

T1

 

LOS

T1

 

RAI

E1, T1

Frame

SL

E1

Frame

Note: When using a common channel signaling process on an E1 trunk, if Blueworx Voice Response detects a fault condition, it automatically sends the correct response to the network. This is in addition to notifying the signaling process by sending the SL_TRUNK_ALARM_REQ primitive. Multiframe level alarms are indicated by setting bit 6 of timeslot 16 of frame 0 to 0 (see ITU-T Recommendation G.704-1991/Table 9). Frame level alarms are indicated by setting bit 3 of timeslot 0 to 1 in those frames which do not carry the frame alignment signal (see ITU-T Recommendation G.704-1991/Table 4a).