The Caller : Subclass variables contain various access
levels and size limits for each subscriber class. Refer to the Blueworx Voice Response for AIX:
Configuring the System information for information about
subscriber classes.
To get the caller subscriber class variables set up for
reference, the Caller - Profile ID variable (SV20)
must be set up. Note that Blueworx Voice Response does
not enforce the subscriber class limits defined by these Read Only
variables. To use these values, they must be referred to by a voice
application.
- Caller : Subclass - ID (SV149)
- This variable
identifies the subscriber class.
- Caller : Subclass : Maximum distribution entries
(SV134)
- This variable contains the
maximum number of entries allowed for each distribution list in the
subscriber class.
- Caller : Subclass : Maximum distribution lists (SV133)
- This
variable contains the maximum number of distribution lists allowed
for each mailbox in the subscriber class.
- Caller : Subclass : Maximum guest mailboxes (SV140)
- This variable contains the maximum
number of guest mailboxes allowed for each application profile in
the subscriber class. The maximum value is 9.
- Caller : Subclass : Maximum number of greetings
(SV135)
- This variable contains the maximum
number of greetings allowed for each mailbox in the subscriber class.
- Caller : Subclass : Maximum number of messages (SV132)
- This variable contains
the maximum number of messages allowed for each mailbox in the subscriber
class.
- Caller : Subclass : Maximum record time (SV141)
- This
variable contains the maximum allowable recording time (in seconds)
for voice messages in the subscriber class. The possible values are
0 through 3600. A value of 0 sets the variable to the system record
limit that is defined in SV179.
- Caller : Subclass : Days before new msgs are deleted (SV565)
- Use
this variable to set the number of days that must elapse before a
new message is deleted. The possible values are 0 through 999. A value
of 0 disables automatic new message deletion.
- Caller : Subclass : Days before saved msgs are deleted (SV566)
- Use this variable
to set the number of days that must elapse before a saved message
is deleted. The possible values are 0 through 999. A value of 0 disables
automatic saved message deletion.
- Caller : Subclass : Max greeting length in secs (SV567)
- Use
this variable to set the maximum allowable recording time (in seconds)
of a subscriber's greeting. The possible values are 0 through 3600.
A value of 0 sets the variable to the system record limit that is
defined in SV179.
- Caller : Subclass : Max audioname length in secs (SV568)
- Use
this variable to set the maximum allowable recording time (in seconds)
of a subscriber's audioname. The possible values are 0 through 3600.
A value of 0 sets the variable to the system record limit that is
defined in SV179.