29825

SIP Register Failed To Contact Registrar

The SIP Register process cannot register a SIP address at this machine with a registrar because a registrar cannot be contacted. The registrar is likely to be out of service. Further contact problems with this registrar will not be alarmed until a successful contact is made.

Check that the Ethernet network is operating correctly, and that the registrar is operational. Check the register configuration files in the $SYS_DIR/voip/ directory for mistakes.

If you are using TLS to connect securely, ensure that you have added the appropriate key to the keystore at $SYS_DIR/voip/keyring.db. You need either the key the registrar is using or a parent key of that key.

If none of the above is successful, contact Blueworx Support.

Severity

Red

Destination

Log, System Monitor