DTJ2013

Node nodename has more applications configured than the maximum recommended limit of default threshold

More than the recommended 30 (default threshold) applications have been defined to start within a given application node.

Reconfigure the Blueworx Voice Response Java and VoiceXML Environment by running the dtjit configuration tool file as described in the “Updating the configuration database” section of the Blueworx Voice Response for AIX manual. Alternatively, redefine the existing groups defined in default.cff manually so that each group contains fewer applications.

As a temporary measure, modify the dtj.node.application.threshold value in the dtj.ini file. Take care when editing dtj.ini and always make a backup copy first! Message DTJ2014 will be issued if the default value of the dtj.node.application.threshold value is modified.