Ensure Blueworx Voice Response has been shut down before running hardware diagnostics (otherwise Blueworx Voice Response will experience unexpected failures).
export RPQPATH=/usr/lpp/devices.iop_rpqthen type the following command, and press Enter:
export PATH=$PATH:/usr/lpp/devices.iop_rpq/binthis may take a few minutes.
rpqtest adapter_number 99 -I
Where adapter_number is the card number corresponding to rpqioadapter_number. You
will be asked to confirm the PCI Mezzanine Connector (PMC) ID (this should
be 0xa1331). rpqtest will proceed through the testing. If the diagnostics
do not find any problems with the adapter, they will end with the message Test completed.rpqtest adapter_number 99 -I -C
where adapter_number is the card number corresponding
to rpqioadapter_number. This is a good reliability test.