The configuration tasks you need to perform depends on how your
network is configured. There are four example configurations provided
here. These particular physical link stations support the exchange
of information between Blueworx Voice Response and any
application running on a System/370, System/390, or AS/400 processor
that communicates through a 3270 data stream using LU 2 protocols.
If your network is not similar to one of the examples, use the
information in the System Management Guide; Communications and Networks,
to determine how to define it.
Example SNA link station
A
In
example A (shown in Figure 1), a Power System is
connected on a token-ring LAN, through an IBM 3174 Establishment Controller,
to an IBM System/370, System/390, or AS/400.
Figure 1. Communications
network, example A
Connecting the pSeries computer to a System/370 or System/390: This procedure describes how to connect the Power System to
a System/370 or System/390 in the configuration shown in Figure 1.
- On the System/370 or System/390: Create an entry in the
VTAM definition file for each downstream physical unit (DSPU): the
IBM 3174 and the Power System.
- Create a logmode entry.
- On the Power System: Use xsnaadmin to
configure the token-ring link station (see Defining a link station using SNA).
- Configure the 3174 to include the address (or alternate address)
of the token-ring adapter in the Power System.
- Start Communications Server for AIX.
Connecting the pSeries computer to an AS/400: This
procedure describes how to connect the Power System to
an AS/400 in the configuration shown in Figure 1.
- On the AS/400: Create a network description object, a controller
description object, and a device description object (one for each
terminal).
- On the Power System: Use xsnaadmin to
configure the token-ring link station (see Defining a link station using SNA).
- Configure the 3174 to include the address (or alternate address)
of the token-ring adapter in the Power System.
- Start Communications Server for AIX.
Example SNA link station
B
In example
B (shown in Figure 2), two Power Systems are
connected on a token-ring LAN, through a communication controller,
to an IBM System/370 or System/390. You can also attach the Power Systems on
the LAN to an AS/400. In this case, the communication controller is
internal to the AS/400.
Figure 2. Communications
network, example B
Connecting the pSeries computer to a System/370 or System/390: This procedure describes how to connect the Power System to
a System/370 or System/390 in the configuration shown in Figure 2.
- On the System/370 or System/390: Create an entry in the
VTAM definition file for each downstream Power System.
- Create an NCP for the communication controller, or alter any existing
NCP to reflect the additional DSPUs.
- Create a logmode entry.
- Reinitialize the communication controller.
- On the Power System: Use xsnaadmin to
configure the token-ring link station (see Defining a link station using SNA).
- Start Communications Server for AIX.
Connecting the pSeries computer to an AS/400: This
procedure describes how to connect the Power System to
an AS/400 in the configuration shown in Figure 2.
- On the AS/400: Create a connection definition object, a
controller description object, and a device description object (one
for each logical device).
- On the Power System: Use xsnaadmin to
configure the token-ring link station (see Defining a link station using SNA).
- Start Communications Server for AIX.
Example SNA link station
C
In example C (shown in Figure 3), a Power System is
connected, using an SDLC connection through a communication controller,
to an IBM System/370 or System/390. You can also attach the Power System to
an AS/400 using an SDLC connection. In this case, the communication
controller is internal to the AS/400
Figure 3. Communications
network, example C
Connecting the pSeries computer to a System/370 or System/390: This procedure describes how to connect the Power System to
a System/370 or System/390 in the configuration shown in Figure 3.
- On the System/370 or System/390: Create an NCP for the
network controller, or alter any existing NCP to reflect the additional
DSPUs.
- Create a logmode entry.
- Reinitialize the communication controller.
- On the Power System: Use xsnaadmin to
configure the SDLC link station (see Defining a link station using SNA).
- Start Communications Server for AIX.
Connecting the pSeries computer to an AS/400: This
procedure describes how to connect the Power System to
an AS/400 in the configuration shown in Figure 3.
- On the AS/400: Create a connection definition object, a
controller description object, and a device description object (one
for each logical device). Create a logmode entry.
- On the Power System: Use xsnaadmin to
configure the SDLC link station (see Defining a link station using SNA).
- Start Communications Server for AIX.
Example SNA link station
D
In example D (shown in Figure 4) up to four Power Systems on
a token-ring LAN are connected to an IBM System/370 or System/390,
using an SDLC connection through an IBM 3174 and a communication controller.
Figure 4. Communications network, example D
Connecting the pSeries computers: This
procedure describes how to connect several Power Systems to
a System/370 or System/390 in the configuration shown in Figure 4.
- On the System/370 or System/390: Create an entry in the
VTAM definition file for each downstream physical unit: the SDLC link
station, the IBM 3174, and the Power Systems.
- Create an NCP for the communication controller, or alter any existing
NCP to reflect the additional DSPUs.
- Create a logmode entry.
- Reinitialize the communication controller.
- On the Power System: Use xsnaadmin to
configure the token-ring link station (see Defining a link station using SNA).
- Configuring the 3174: Configure the 3174 to include the
address of the token-ring adapter in the Power System.
- Start Communications Server for AIX.