Communications Server for AIX manages only the Power System. Other components on the network may require additional information before they can communicate with Blueworx Voice Response. For example, when the network connects the Power System to a remote computer through a communication controller, both the remote computer and the controller need to be made aware that the Power System is part of the network. When the connection is to an IBM System/370 processor, the VTAM definition file needs to include the Power System.
You must define to VTAM a physical unit (PU) with at least one logical unit (LU) for communication to the Power System. Define the PU with a MAXDATA parameter of at least 256 and PUTYPE=2. All other parameters are dependent on the connection type to the host. Define at least one LU for 3270 emulation. Define the 3270 emulation LU with the following parameters:
Nonnegotiable bind
FM Profile (FMPROF)=3
TS Profile (TSPROF)=3
FM usage-Primary LU protocols (PRIPROT)=x'11',x'21',x'31',x'91',x'A1', or x'B1'
FM usage-Secondary LU protocols (SECPROT)=x'B0',x'90', or x'A0' for displays, also x'10',x'20',x'30' for printers.
FM usage-Common LU Protocols (COMPROT)=x'3080',x'7080' for LU1 printers.
Pacing=none required
LU type=LU2 (PSERVIC = x'028000000000000000000200')
or
LU type=LU3 (PSERVIC = x'038000000000648400007E00')
or
LU type=LU1 (PSERVIC = x'01000000E100000000000000')
The values specified for the PSERVIC fields are not the only valid values that can be entered. The PSERVIC field controls the LU type and screen or print buffer options and sizes. Other valid 3270 settings can be used in this field.
Use this procedure to help you configure your mainframe computer to communicate with Blueworx Voice Response over a TCP/IP network. For complete instructions see Communications Server for AIX: Administration Guide. Additional information is provided in the IBM Redbook Migrating Subarea Networks to an IP Infrastructure Using Enterprise Extender.
AP24XCAE VBUILD TYPE=XCA IYCOZXP1 PORT MEDIUM=HPRIP, IPTOS=(20,40,80,C0) LIVTIME=10, SAPADDR=8, SRQRETRY=3 SRQTIME=15 IYCOZXG1 GROUP DIAL=YES,CALL=INOUT, DYNPUPFX=IY, DYNPU=YES, AUTOGEN=(24,EEL,EEP) Switched XCA major node Switched major node configuration AP24SMNX VBUILD TYPE=SWNET IYCOR000 PU PUTYPE=2, CPNAME=NETLEY, ADDR=01, ASDP=YES, NETID=GBIBMIYA, CPCP=YES, CONNTYPE=APPN, TGN=3, USE 3 FOR ENTERPRISE EXTENDER HPR=YES, DWACT=NO, XID=YES, TGP=TRING16M, USE THIS TG PROFILE IN IBMTGPS ISTATUS=ACTIVE * IYCOP000 PATH IPADDR=0.00.00.00, IP ADDR OF WORK STATION GRPNM=IYCOZXG1 REFERS TO GROUP NAME IN XCA MAJNODE
AP24SMNY VBUILD TYPE=SWNET IYCOR00A PU PUTYPE=2, IDBLK=071, IDNUM=1111A, MODETAB=SNATERM#, LOGTAB=LOGTAB00, USSTAB=UTCPPTOK, SSCPFM=USSSCS, VPACING=0,PACING=0, ISTATUS=ACTIVE * IYCOT042 LU LOCADDR=2,ISTATUS=ACTIVE IYCOT043 LU LOCADDR=3,ISTATUS=ACTIVE IYCOT044 LU LOCADDR=4,ISTATUS=ACTIVE IYCOT045 LU LOCADDR=5,ISTATUS=ACTIVE etc to IYCOT743 LU LOCADDR=255,ISTATUS=ACTIVE * * Example of an additional DLUR connection IYCOR005 PU PUTYPE=2, IDBLK=071, IDNUM=11115, MODETAB=SNATERM#, LOGTAB=LOGTAB00, INTERPRET TABLE IN SYS2.VTAMLIB USSTAB=UTM24TOK, SSCPFM=USSSCS, VPACING=0,PACING=0, ISTATUS=ACTIVE * IYCOT051 LU LOCADDR=1,ISTATUS=ACTIVE IYCOT052 LU LOCADDR=2,ISTATUS=ACTIVE IYCOT053 LU LOCADDR=3,ISTATUS=ACTIVE IYCOT054 LU LOCADDR=4,ISTATUS=ACTIVE IYCOT055 LU LOCADDR=5,ISTATUS=ACTIVE IYCOT056 LU LOCADDR=6,ISTATUS=ACTIVE