Configuring IBM_Trombone_Custom_Server

IBM_Trombone_Custom_Server has a number of command-line parameters that you can set to help debug problems, or to fine tune the operation of the custom server. These are defined here.

The command-line parameters are defined in Table 1.

Table 1. Configuration options for IBM_Trombone_Custom_Server.

Parameter

Default

Description

-d

off

Provide extra debugging information (over and above the normal information that always gets sent).

-s

off

Print debugging information to stdout as well as to AIX system trace.

-a

off

Send extra Information alarms to the error log.

-pn

n=0.1

Number of child helper processes to run.

See About child helper processes for information about setting this parameter.

-en

0

The event data (n) sent by the custom server if the third party hangs up (see the Blueworx Voice Response for AIX: Custom Servers information: CA_Report_Channel_Event()).

-in

0

The information field (n) sent by the custom server if the third party hangs up (see the Blueworx Voice Response for AIX: Custom Servers information: CA_Report_Channel_Event()).

-z

off

This parameter is for test purposes only. It causes the custom server to enrol one of each type of error possible on custom server start-up, then terminates. The enrolment of errors takes about 30 seconds.