Templates are provided for the signaling protocols that are listed here.
This section describes the values of the Blueworx Voice Response system parameters as they are supplied in each template. Because so many templates are available, they are described in four tables; to find the table that you want, see Table 1.1
Signaling Protocol | Parameters Are Listed in |
---|---|
Aspect E&M |
|
DID (T1) |
|
E&M - including ROLM 9751 (9006) |
|
EL7/CAS (Ericsson MD110) (E1) |
|
FXS and SAS Loop Start |
|
FXS Ground Start |
|
Italy (E1) |
|
R2 Digital Line Signaling (E1) |
|
RE (Remote Extension) (E1) |
|
ROLM 9751 (9005) E&M |
|
ROLM 9751 (9005) FXS Loop Start |
|
SL (Subscriber Loop) (E1) |
|
TS003/P2 Line Signaling (E1) |
|
U.K. CallStream (E1) |
|
U.K. Exchange (E1) |
|
U.K. Tie/DDI (E1) |
System Parameter | Access Level | DID (T1) | E&M - including ROLM 9751 (9006) | ROLM 9751 (9005) E&M | Aspect E&M | FXS Ground Start |
---|---|---|---|---|---|---|
Answer Delay Time | Admin | 260 ms | 260 ms | 260 ms | ||
Blocking Action | Field | Offhook | Offhook | Offhook | Other | Other |
Cadence Energy Maximum | Admin | 0 dBm | 0 dBm | 0 dBm | 0 dBm | 0 dBm |
Cadence Energy Minimum | Admin | -28 dBm | -28 dBm | -28 dBm | -28 dBm | -28 dBm |
Cadence Off Time Maximum | Admin | 600 ms | 600 ms | 600 ms | 600 ms | 600 ms |
Cadence Off Time Minimum | Admin | 400 ms | 400 ms | 400 ms | 400 ms | 400 ms |
Cadence On Time Maximum | Admin | 600 ms | 600 ms | 600 ms | 600 ms | 600 ms |
Cadence On Time Minimum | Admin | 400 ms | 400 ms | 400 ms | 400 ms | 400 ms |
Cadence Silence Maximum | Admin | -28 dBm | -28 dBm | -28 dBm | -28 dBm | -28 dBm |
CO Acknowledgment | Field | 60 ms | 60 ms | 60 ms | 60 ms | 60 ms |
CO Off-Hook | Field | 60 ms | 60 ms | 60 ms | 60 ms | 60 ms |
CO On-Hook | Field | 700 ms | 200 ms | 200 ms | 200 ms | 40 ms |
Constant Energy Maximum | Admin | 0 dBm | 0 dBm | 0 dBm | 0 dBm | 0 dBm |
Constant Energy Minimum | Admin | -24 dBm | -24 dBm | -24 dBm | -24 dBm | -24 dBm |
Delay Start Delay | Field | 120 ms | 120 ms | 120 ms | 120 ms | |
Delay Start Duration | Field | 200 ms | 200 ms | 200 ms | 200 ms | |
Dial Pause | Admin | 200 ms | 200 ms | 600 ms | 200 ms | |
Dial Tone Qualify Time | Admin | 200 ms | 200 ms | 200 ms | 200 ms | |
Dial Tone (Detection) Timeout | Admin | 8000 ms | 8000 ms | 8000 ms | 8000 ms | |
Glare Detection Time | Field | 40 ms | 40 ms | 40 ms | 40 ms | 40 ms |
Ground Flash | Field | |||||
Hangup Detection | Admin | Off | Off | Off | Off | Off |
Hook Flash | Admin | 300 ms | 300 ms | 500 ms | 500 ms | |
Incoming Address Register Type | Admin | Fixed Length | Fixed Length | Fixed Length | Fixed Length | |
Incoming Guard Time | Field | 0 ms | 0 ms | 0 ms | 0 ms | 40 ms |
No Answer Warning | Admin | 120000 ms | 120000 ms | 120000 ms | 120000 ms | 120000 ms |
Outgoing Address Register Type | Admin | Fixed Length | Fixed Length | Fixed Length | Fixed Length | Fixed Length |
Outgoing Guard Time | Field | 1000 ms | 1000 ms | 1000 ms | 1000 ms | |
Reconnect Call Feature Code | Admin | H | H\5*1 | H | H | |
Reconnect Call Request Signal | Admin | Hook Flash | Feature Code | Hook Flash | Hook Flash | |
Register Length | Admin | 5 | 5 | 5 | 5 | 5 |
Ringing Off Maximum | Admin | 5000 ms | ||||
Ringing Off Minimum | Admin | 400 ms | ||||
Ringing On Maximum | Admin | 2400ms | ||||
Ringing On Minimum | Admin | 600 ms | ||||
Seize Acknowledgment Timeout | Field | 200 ms | ||||
T1 CAS Signaling Format | Admin | 2-bit AB (SF) | 2-bit AB (SF) | 2-bit AB (SF) | 2-bit AB (SF) | 2-bit AB (SF) |
Transfer Call Feature Code | Admin | H | H\5*7\5 | H. | H | |
Transfer Call Request Signal | Admin | Hook Flash | Feature Code | Feature Code | Hook Flash | |
Wink Start Delay | Field | 120 ms | 120 ms | 120 ms | 120 ms | |
Wink Start Duration | Field | 200 ms | 200 ms | 200 ms | 200 ms |
System Parameter | Access Level | FXS and SAS Loop Start | ROLM 9751 (9005) FXS Loop Start | Italy (E1) | RE (Remote Extension) (E1) |
---|---|---|---|---|---|
Answer Delay Time | Admin | ||||
Blocking Action | Field | Offhook | Offhook | Offhook | Offhook |
Cadence Energy Maximum | Admin | 0 dBm | 0 dBm | 0 dBm | 0 dBm |
Cadence Energy Minimum | Admin | -28 dBm | -28 dBm | -28 dBm | -28 dBm |
Cadence Off Time Maximum | Admin | 600 ms | 600 ms | 600 ms | 600 ms |
Cadence Off Time Minimum | Admin | 400 ms | 400 ms | 400 ms | 400 ms |
Cadence On Time Maximum | Admin | 600 ms | 600 ms | 600 ms | 600 ms |
Cadence On Time Minimum | Admin | 400 ms | 400 ms | 400 ms | 400 ms |
Cadence Silence Maximum | Admin | -28 dBm | -28 dBm | -28 dBm | -28 dBm |
CO Acknowledgment | Field | 60 ms | 60 ms | 20 ms | 60 ms |
CO Off-Hook | Field | 40 ms | |||
CO On-Hook | Field | 160 ms | |||
Constant Energy Maximum | Admin | 0 dBm | 0 dBm | 0 dBm | 0 dBm |
Constant Energy Minimum | Admin | -24 dBm | -24 dBm | -24 dBm | -24 dBm |
Delay Start Delay | Field | ||||
Delay Start Duration | Field | ||||
Dial Pause | Admin | 200 ms | |||
Dial Tone Qualify Time | Admin | 200 ms | 200 ms | 200 ms | |
Dial Tone (Detection) Timeout | Admin | 8000 ms | 8000 ms | 8000 ms | |
Glare Detection Time | Field | 40 ms | 40 ms | 40 ms | 40 ms |
Ground Flash | Field | 120 ms | |||
Hangup Detection | Admin | Constant Energy Detection | Constant Energy Detection | Off | Constant Energy Detection |
Hook Flash | Admin | 500 ms | 500 ms | 100 ms | |
Incoming Address Register Type | Admin | ||||
Incoming Guard Time | Field | 860 ms | 860 ms | 100 ms | 860 ms |
No Answer Warning | Admin | 120000 ms | 120000 ms | 120000 ms | 120000 ms |
Outgoing Address Register Type | Admin | ||||
Outgoing Guard Time | Field | 1500 ms | 1500 ms | 100 ms | 1500 ms |
Reconnect Call Feature Code | Admin | H | H\5*1 | H | |
Reconnect Call Request Signal | Admin | Hook Flash | Feature Code | Hook Flash | |
Register Length | Admin | ||||
Ringing Off Maximum | Admin | 5000 ms | 5000 ms | 5000 ms | |
Ringing Off Minimum | Admin | 400 ms | 400 ms | 300 ms | |
Ringing On Maximum | Admin | 2400 ms | 2400 ms | 1260 ms | |
Ringing On Minimum | Admin | 600 ms | 600 ms | 220 ms | |
Seize Acknowledgment Timeout | Field | ||||
T1 CAS Signaling Format | Admin | 2-bit AB (SF) | 2-bit AB (SF) | ||
Transfer Call Feature Code | Admin | H | H\5*7\5 | H | |
Transfer Call Request Signal | Admin | Hook Flash | Feature Code | Hook Flash | |
Wink Start Delay | Field | ||||
Wink Start Duration | Field |
System Parameter | Access Level | SL (Subscriber Loop) (E1) | U.K. CallStream (E1) | U.K. Exchange (E1) | U.K. Tie/DDI (E1) | EL7/CAS (Ericsson MD110) (E1) |
---|---|---|---|---|---|---|
Answer Delay Time | Admin | 260 ms | ||||
Blocking Action | Field | Offhook | Offhook | Offhook | Offhook | Offhook |
Cadence Energy Maximum | Admin | 0 dBm | 0 dBm | 0 dBm | 0 dBm | 0 dBm |
Cadence Energy Minimum | Admin | -28 dBm | -28 dBm | -28 dBm | -28 dBm | -28 dBm |
Cadence Off Time Maximum | Admin | 600 ms | 600 ms | 600 ms | 600 ms | 600 ms |
Cadence Off Time Minimum | Admin | 400 ms | 400 ms | 400 ms | 400 ms | 400 ms |
Cadence On Time Maximum | Admin | 600 ms | 600 ms | 600 ms | 600 ms | 600 ms |
Cadence On Time Minimum | Admin | 400 ms | 400 ms | 400 ms | 400 ms | 400 ms |
Cadence Silence Maximum | Admin | -28 dBm | -28 dBm | -28 dBm | -28 dBm | -28 dBm |
CO Acknowledgment | Field | 60 ms | 20 ms | 20 ms | 20 ms | |
CO Off-Hook | Field | 20 ms | 0 ms | 60 ms | 40 ms | |
CO On-Hook | Field | 200 ms | 160 ms | 160 ms | 160 ms | |
Constant Energy Maximum | Admin | 0 dBm | 0 dBm | 0 dBm | 0 dBm | 0 dBm |
Constant Energy Minimum | Admin | -24 dBm | -24 dBm | -24 dBm | -24 dBm | -24 dBm |
Delay Start Delay | Field | 20 ms | ||||
Delay Start Duration | Field | 160 ms | ||||
Dial Pause | Admin | 2700 ms | 200 ms | 200 ms | ||
Dial Tone Qualify Time | Admin | 1000 ms | 200 ms | 200 ms | ||
Dial Tone (Detection) Timeout | Admin | 12000 ms | 60000 ms | 8000 ms | ||
Glare Detection Time | Field | 40 ms | 40 ms | 40 ms | 40 ms | |
Ground Flash | Field | |||||
Hangup Detection | Admin | Off | Off | Off | Off | Off |
Hook Flash | Admin | 100 ms | 100 ms | |||
Incoming Address Register Type | Admin | Fixed Length | ||||
Incoming Guard Time | Field | 500 ms | 100 ms | 100 ms | 100 ms | 860 ms |
No Answer Warning | Admin | 120000 ms | 120000 ms | 120000 ms | 120000 ms | 120000 ms |
Outgoing Address Register Type | Admin | Fixed Length | ||||
Outgoing Guard Time | Field | 6000 ms | 2000 ms | 360 ms | 1500 ms | |
Reconnect Call Feature Code | Admin | |||||
Reconnect Call Request Signal | Admin | |||||
Register Length | Admin | 5 | ||||
Ringing Off Maximum | Admin | 2400 ms | ||||
Ringing Off Minimum | Admin | 100 ms | ||||
Ringing On Maximum | Admin | 500 ms | ||||
Ringing On Minimum | Admin | 300 ms | ||||
Seize Acknowledgment Timeout | Field | |||||
T1 CAS Signaling Format | Admin | |||||
Transfer Call Feature Code | Admin | H | ||||
Transfer Call Request Signal | Admin | Signaling | ||||
Wink Start Delay | Field | |||||
Wink Start Duration | Field |
System Parameter | Access Level | R2 Digital Line Signaling (E1) | TS003/P2 Line Signaling (E1) |
---|---|---|---|
Answer Delay Time | Admin | 260 ms | 260 ms |
Blocking Action | Field | Offhook | Offhook |
Cadence Energy Maximum | Admin | 0 dBm | 0 dBm |
Cadence Energy Minimum | Admin | -28 dBm | -28 dBm |
Cadence Off Time Maximum | Admin | 600 ms | 600 ms |
Cadence Off Time Minimum | Admin | 400 ms | 400 ms |
Cadence On Time Maximum | Admin | 600 ms | 600 ms |
Cadence On Time Minimum | Admin | 400 ms | 600 ms |
Cadence Silence Maximum | Admin | -28 dBm | -28 dBm |
CO Acknowledgment | Field | 60 ms | 60 ms |
CO Off-Hook | Field | 60 ms | 60 ms |
CO On-Hook | Field | 200 ms | 200 ms |
Constant Energy Maximum | Admin | 0 dBm | 0 dBm |
Constant Energy Minimum | Admin | -24 dBm | -24 dBm |
Delay Start Delay | Field | ||
Delay Start Duration | Field | ||
Dial Pause | Admin | 200 ms | 200 ms |
Dial Tone Qualify Time | Admin | 200 ms | 200 ms |
Dial Tone (Detection) Timeout | Admin | 8000 ms | 8000 ms |
Glare Detection Time | Field | 40 ms | 100 ms |
Ground Flash | Field | ||
Hangup Detection | Admin | Off | Off |
Hook Flash | Admin | 100 ms | 100 ms |
Incoming Address Register Type | Admin | Fixed Length | Fixed Length |
Incoming Guard Time | Field | 100 ms | 80 ms |
No Answer Warning | Admin | 120000 ms | 120000 ms |
Outgoing Address Register Type | Admin | Fixed Length | Fixed Length |
Outgoing Guard Time | Field | 1000 ms | 120 ms |
Reconnect Call Feature Code | Admin | ||
Reconnect Call Request Signal | Admin | ||
Register Length | Admin | 5 | 5 |
Ringing Off Maximum | Admin | ||
Ringing Off Minimum | Admin | ||
Ringing On Maximum | Admin | ||
Ringing On Minimum | Admin | ||
Seize Acknowledgment Timeout | Field | 200 ms | 800 ms |
T1 CAS Signaling Format | Admin | ||
Transfer Call Feature Code | Admin | H | H |
Transfer Call Request Signal | Admin | ||
Wink Start Delay | Field | ||
Wink Start Duration | Field |