27033

SDI re-enable notification

SDI has scheduled a re-enable request for this pack. An unrecoverable error had previously been detected, which required the pack to be disabled. The pack will shortly return to service. Should the re-enable fail it will be retried the number of times specified by the "Maximum Retries for Pack/Adapter Reenabling" parameter in the General parameter group in System Configuration, with progressively increasing time delays between each attempt.

Check that the pack is re-enabled. If the pack correctly returns to service the problem was probably temporary and can be ignored unless it occurs repeatedly. If the pack continues to be enabled and disabled, manually remove the pack from service and run diagnostics on it when convenient. Check also that all cables are firmly in place, that the pack is securely fitted in the 9295 (if relevant), and that all the adapters in the pSeries computer are correctly seated.

Severity

White

Destination

Log, System Monitor