This test attempts to identify why the D7 package is not working on a machine that is configured for Blueworx Voice Response Client operation. Perform the following steps:
*************************** *** D7 Process checking *** *************************** PID STAT MODE HOST MUX OBJECT 124806 ok LX|A b80e spm/0 daemon [name=apmd] 124234 ok LX|A b80e spm/2 daemon [name=mlogd] 43552 ok LX|A b80e spm/3 daemon [name=spmd] 36588 ok LX|A b80e spm/4 daemon [name=netd] 147110 ok LX|A b80e spm/5 daemon [name=alarmd] 147110 ok L|A b80e spm/6 nmdobj [name=AlarmExt] 108324 ok LX|A b80e spm/7 daemon [name=dsmd] 153932 ok LX|A b80e spm/8 daemon [name=dkmd] 43802 ok L|A b80e spm/10 nmdobj [name=ebs_ps] ************ *** SUCCESS : D7 system configured for WVR operation ************
Message | Action |
---|---|
SUCCESS : D7 system configured for SS7 Server . | Go to stage 3a |
SUCCESS : D7 system configured for WVR operation | Go to stage 3b |
FAILED : D7 system is not running | Go to stage 3c |
FAILED : MTP-3(upmd) is not running | Go to stage 3a |
FAILED : ISUP(isupd) is not running. | Go to stage 3a |
If this machine was not present in a Stage 2 test, proceed to Stage 5
It appears that the D7 package is not running. Try using option D of SS7_MAINT to start the D7 package. Using the M option may offer useful information as to why it does not start.