D7WVRErrorReport is a second custom server of the D7 Enablement package.
Its sole purpose is to translate Alarm messages from the D7 package into Blueworx Voice Response Alarm messages.
Translated messages can be collected from the local D7 package, or can
be received globally from any D7 package on the SS7 cluster. A number of D7
alarm messages have their own translation, with parameters translated into
more identifiable values (for example machine names) and descriptions to highlight
the condition and potential remedies.
Startup parameters
The startup parameters listed below can be applied to the custom server
from the top level Blueworx Voice Response GUI, after making the following selections: Application —> Application —> SS7_D7 —> Custom servers —> D7WVRErrorReport —> File —>Properties.
Remember to put only one parameter on each line.
- Global Reporting
- Use the -g parameter (together with -r) to register this D7 host as
a global collector of D7 alarms from other D7 hosts (SS7 Servers). See D7 Alarm Logging.
- Repetition Suppression
- Use the –R <number> facility to reduce the number of repetitions
of the same Alarm message being passed to Blueworx Voice Response. For example
by entering –R 3 following the first occurrence of an alarm causes
the subsequent three identical alarms to be suppressed. Use the –r
parameter to disable this feature.
- Reporting Level
- Use the –d <1...3> parameter to define the reporting level.
For an Alarm message to be passed to Blueworx Voice Response it must have
a reporting level of greater than or equal to the parameter supplied. For
example –d 1 is the default and passes all alarm messages.
- Compile Translation File
- Use –C to create a binary translation file based on the D7 package
error files. This option is used once on installation, to create a translation
file from D7 to Blueworx Voice Response, and is not required during normal
operation.
- Configuration Files
- D7WVRErrorReport has two configuration files:
- D7_ErrorList
- The binary translation file created by the Compile Translation file
option above.
- AlarmTranslation.cfg
- This contains the mapping of D7 error codes to Blueworx Voice Response
alarm codes and associated reporting level. For more information on this configuration
refer to Configuration files.