The system displays the existing values of the parameters that apply to all channels assigned to this group.
Parameter |
Setting |
---|---|
Call information type |
Set this parameter to Signaling Process. |
Signaling process type |
Set this parameter as appropriate:
|
Area code |
Set this to a 1- to 6-character value. |
In the event that called number information is not received, the Area Code value is used with the Phone Number parameter of the channel, to create the channel identification to be used to find the application profile. |
Parameter |
Values for fixed length incoming register signaling |
Values for feature group D incoming register signaling |
---|---|---|
Call information type |
Set this parameter to Register. |
Set this parameter to Register. |
Incoming address signaling type |
Set this parameter to MFR1, DTMF, or Dial Pulse, depending on the capabilities of your switch. Note that the incoming and outgoing address signaling types are normally the same. |
Set this parameter to MFR1. |
Signaling process type |
Set this parameter to None. |
Set this parameter to None. |
Area code |
Set this to a 1- to 6-character value. |
Set this to a 1- to 6-character value. |
In the event that called number information is not received, the Area Code value is used with the Phone Number parameter of the channel, to create the channel identification to be used to find the application profile. |
Call information type |
Set this parameter to None, which is the default. |
---|---|
Signaling process type |
Set this parameter to None, which is the default. |
Area code |
Set this to a 1- to 6-character value. In the event that called number information is not received, the Area Code value is used with the Phone Number parameter of the channel, to create the channel identification that is to be used to find the application profile. |
Parameter |
Values SMSI, SMDI or VMS |
Values for ACL |
Values for CallPath_SigProc |
---|---|---|---|
Call information type |
Set this parameter to Signaling Process. |
Set this parameter to Signaling Process. |
Set this parameter to Signaling Process. |
Signaling process type |
Set this parameter to SMSI/SMDI/VMS. |
Set this parameter to ACL. |
Set this parameter to User1. |
Area code |
Set this parameter to the 1- to 6-character prefix that is to be used for all channels in the channel group. The area code is concatenated to the dialed number sent on the exchange data link. |
Set this parameter to the 1- to 6-character prefix that is to be used for all channels in the channel group. The area code is concatenated to the dialed number sent on the exchange data link. |
Set this parameter to the 1- to 6-character prefix that is to be used for all channels in the channel group. The area code is concatenated to the dialed number sent on the exchange data link. |
Anything else? Review the explanations of the remaining parameters that are listed in Channel parameter group or in the online help. If any of the values are not suitable for use with your switch, change them.
Although the System Configuration window is still displayed, the system has saved the parameter values for the channel group.