Wink Start Delay (ms)

Parameter group

Signaling Type

Access level

Field

Possible values

100 through 5000

Defaults

120

Explanation

Specifies how much time elapses after Blueworx Voice Response receives the off hook signal from the switch but before it sends the wink start signal to the switch. This parameter is important only when channels are using wink start as the start type. The start type is determined by one of the Start Type parameters in the Channel Group parameter group.