Time On 2 Minimum (0.001 Seconds)

Parameter group

Call Progress Tones

Access level

Field

Possible values

Integer multiples of 20, in the range 0 through 50000

Defaults

0

Explanation

With Time On 2 Maximum, Time Off 2 Minimum, and Time Off 2 Maximum, defines how long the second frequency component of the call progress tone continues. For more information, see Setting call progress tone parameters for outbound dialing.