SDI Timeout - Signaling Process Reconfiguration

Parameter group

General

Access level

Field

Possible values

0 through 3600 seconds

Defaults

60 seconds

Explanation

Specifies the maximum time Blueworx Voice Response is to wait for all registered signaling processes to respond to an SL_RECONFIG_TRUNK _REQ primitive with an SL_RECONFIG_TRUNK _CNF primitive. After this time, Blueworx Voice Response continues enabling the trunk, but it is possible that out-of-date configuration data might be in use.

On a heavily loaded system with many registered signaling processes, it might be necessary to increase this value, but do not change it unless you understand exactly what you are doing. Otherwise you might badly affect the operation of the system. If you have problems, return to the default value.