E1 CAS Protocol

Parameter group

Channel Group

Access level

Admin

Possible values

E&M/US
EL7/CAS (Ericsson MD110)
FXS
Italy
RE
R2
SL
TS003
UK Tie/DDI
UK Callstream
UK Exchange

Defaults

R2

Explanation

Specifies the E1 channel associated signaling (CAS) protocol that is used by channels in this group. This parameter is not used with common channel signaling (CCS).

Note: UK Tie/DDI can also be used whenever “inverted” E&M/US (also known as European E&M) signaling is required. Because it is not possible to select Wink Start for the UK Tie/DDI Start Type parameter when required, wink start operation can be simulated by setting UK Tie/DDI Start Type to Delay Start, provided the default values are used for Delay Start Delay and Delay Start Duration.