BRM Configuration Options

This section is used to configure BVR to work as part of a system of machines managed by Blueworx Resource Manager (BRM).

This section is OPTIONAL

The header for this section is [brm]

Table 1. brm
Name Mandatory Type Default Description
address no string localhost Specifies a comma separated list of the addresses of the BRM systems. For example "brm1,brm2".
port no integer 9696 Specifies the port to connect to the BRM system, must match the clientPort in the BRM zoo.cfg.

Min: 1, Max: 65535