Secure SIP configuration settings for incoming calls

The various configuration settings that can be modified to influence secure SIP usage within incoming calls are described.

Certificate usage must have previously been set up as described in Secure SIP minimal configuration.

The configuration parameters that influence secure SIP usage within incoming calls are as follows:

Enable Secure SIP
When set to Yes, Blueworx Voice Response attempts to accept incoming calls that are made using TLS. When set to No, Blueworx Voice Response ignores incoming calls that are made using TLS. The default value is No.
Call Signalling Secure Port
Specifies the port that Blueworx Voice Response listens on for incoming calls made using TLS. The default value is 5061.

Incoming calls using TCP or UDP will always be accepted, regardless of these settings.