Caller : Subscriber Class variables

The Caller : Subclass variables contain various access levels and size limits for each subscriber class. Refer to the Blueworx Voice Response for AIX: Configuring the System information for information about subscriber classes.

To get the caller subscriber class variables set up for reference, the Caller - Profile ID variable (SV20) must be set up. Note that Blueworx Voice Response does not enforce the subscriber class limits defined by these Read Only variables. To use these values, they must be referred to by a voice application.

Caller : Subclass - ID (SV149)
This variable identifies the subscriber class.
Caller : Subclass : Maximum distribution entries (SV134)
This variable contains the maximum number of entries allowed for each distribution list in the subscriber class.
Caller : Subclass : Maximum distribution lists (SV133)
This variable contains the maximum number of distribution lists allowed for each mailbox in the subscriber class.
Caller : Subclass : Maximum guest mailboxes (SV140)
This variable contains the maximum number of guest mailboxes allowed for each application profile in the subscriber class. The maximum value is 9.
Caller : Subclass : Maximum number of greetings (SV135)
This variable contains the maximum number of greetings allowed for each mailbox in the subscriber class.
Caller : Subclass : Maximum number of messages (SV132)
This variable contains the maximum number of messages allowed for each mailbox in the subscriber class.
Caller : Subclass : Maximum record time (SV141)
This variable contains the maximum allowable recording time (in seconds) for voice messages in the subscriber class. The possible values are 0 through 3600. A value of 0 sets the variable to the system record limit that is defined in SV179.
Caller : Subclass : Days before new msgs are deleted (SV565)
Use this variable to set the number of days that must elapse before a new message is deleted. The possible values are 0 through 999. A value of 0 disables automatic new message deletion.
Caller : Subclass : Days before saved msgs are deleted (SV566)
Use this variable to set the number of days that must elapse before a saved message is deleted. The possible values are 0 through 999. A value of 0 disables automatic saved message deletion.
Caller : Subclass : Max greeting length in secs (SV567)
Use this variable to set the maximum allowable recording time (in seconds) of a subscriber's greeting. The possible values are 0 through 3600. A value of 0 sets the variable to the system record limit that is defined in SV179.
Caller : Subclass : Max audioname length in secs (SV568)
Use this variable to set the maximum allowable recording time (in seconds) of a subscriber's audioname. The possible values are 0 through 3600. A value of 0 sets the variable to the system record limit that is defined in SV179.