Successful far end hang-up (exchange data link)

This section describes the sequence of events during far end hang-up.

Figure 1. Exchange data link: successful far end hang-up
The graphic is a very simplified representation of the process described in detail in the next section.

Description of flows

The flows shown in Figure 1 are as follows:

  1. There is a connected call, which was established using channel associated signaling.
  2. The network sends hang-up notification for the call over the exchange data link.
  3. The signaling process notifies Blueworx Voice Response that the call has been cleared. The signaling process creates an SL_CALL_TERMINATE_IND primitive, and sends it to Blueworx Voice Response using the sl_send_indication() subroutine call.
  4. Blueworx Voice Response terminates the current state table action with the Caller Hung Up result.