Reconnect Call Feature Code

Parameter group

Signaling Type

Access level

Admin

Possible values

A character string

Defaults

H

Explanation

Specifies up to 16 characters that control signals sent to the switch to reconnect a call. It is important to correctly specify the code that the switch requires for the feature to operate. The characters are:

0 through 9, #, *, A, B, C, or D
Send the digit or character.
H
Send a “hook flash” signal. Do not wait for dial tone.
G
Send a “ground key” signal. Do not wait for dial tone.
. (period)
Wait for dial tone. The maximum time to wait is specified by the Pause parameter on the ReconnectCall action or, if its value is 0, by the Maximum Dial Tone Wait system parameter.
, (comma)
Pause for the time that is specified by the Pause parameter on the ReconnectCall action.
\n
Pause for the time that is specified in n-tenths of a second (one digit only).

Example: Set this value to H\5*1 to reconnect a call on a switch that is configured to:

  1. Accept a Hook Flash
  2. Delay 0.5 seconds
  3. Send *1.

When Reconnect Call Request Signal is set to Signaling, this parameter does not apply; in this condition, hook flash is the method used to request a reconnection.